Pole position identification (PPI) with Hiperface absolute value encoder: identified pole position is very imprecise (corrected from V1.5.6)

Corrected from:
- i700 servo inverter V01.05.06.9665

Response of the new version:
The pole position identified during the pole position identification is as exact as expected/required.
 

What happens?
The pole position identified during the pole position identification (PPI) significantly deviates from the actual pole position (+/-10°).
If necessary, the plausibility monitoring of the PPI will respond.  
 
When does the problem occur?
The problem occurs in the case of a pole position identification (PPI) with feedback via Hiperface SinCos absolute value encoder.
 
Which products are affected?
- i700 servo inverter ≤ V01.04.00.9125

Short-term measures/recommendations:
None.
 
Evaluation:
With synchronous motors, large deviations in the pole position information significantly affect the torque generation.
Possibly, the torque required for the application cannot be supplied.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400222/1/