Corrected from:
- i700 servo inverter (encoder hardware variant) V01.05.06.9665
Response of the new version:
Encoder parameters are read correctly via the 'Encoder identification' function in the PLC Designer.
What happens?
Hiperface SinCos absolute value encoders of type 'TTK70': Encoder parameters are not read out correctly via the 'Encoder identification' function.
In the PLC Designer dialog, oscillating values are displayed for the serial number, the identified type code, and the encoder identification status.
Operation is not possible with this encoder.
When does this behaviour occur?
Every time after switching on the inverter.
Which products are affected?
- i700 servo inverter (encoder hardware variant) ≤ V01.04.00.9125
Short-term measures:
None.
Evaluation/recommendations:
i700 versions <= 01.04.00 do not support any linear encoder functionality.