Function blocks can also be used in the I/O interconnection (8400 StateLine and HighLine from V11.0, TopLine from V02.0)

Which products are affected?
StateLine with firmware version V11.00
HighLine with firmware version V11.00
TopLine with firmware version V02.00

Functional description
So far function blocks in the FB Editor could only be used in the application interconnection. If e.g. I/O or bus system input signals were to be linked to a logic function, the signals had to be integrated in the application interconnection first because it was the only place where the corresponding function blocks could be inserted.
From the above-mentioned firmware versions, the function blocks can now be used in the I/O interconnection, too. That way, logic operations or arithmetic functions can also be carried out in the I/O interconnection. The signal interconnection and the diagnostics of the signal flow are highly simplified.
For that purpose, many function blocks have been added which are available from these firmware versions.

Applications
Easier inverter management while retaining user interfaces.