Behaviour of the new version?
The zero pulse is correctly indicated at the digital frequency output X10 when the incremental encoder simulation is selected.
What happens?
The zero pulse is not indicated at the digital frequency output (X10).
When does the problem occur?
The response described before occurs sporadically if code C0540 (= DFOUT_IO function) is configured to 2 (= incremental encoder simulation + zero pulse) and the touch probes for the DFIN system block as well as for MCTRL (E4 and E5) are used.
Which products are affected?
EVS93xx-EI (Servo PLC V8.0)
EVS93xx-ET (Servo PLC V8.0 with technology function)
Possible diagnostics?
None.
Short-term measures/recommendations?
None.
Evaluation:
If the incremental encoder simulation is selected the zero pulse is sporadically not indicated at the digital frequency output.