Error reset accepted without delay (from V2.3)

Which products are affected?
8400 BaseLine D (as of Firmware V2.3)

Function description
If the inverter changes to the 'Fail' error state due to any event (user error, Ixt monitoring, etc.), this state can be acknowledged immediately after appearance of the error (Fail Reset).
According to the Lenze default setting the 'Fail Reset' function is connected to the digital input 'RFR' (controller enable).

Important:
There are no delays which have to be considered from appearance to acknowledgement of the error.

The behaviour of firmware version 2.3 is not incompatible with 'lower' firmware versions.

Applications
It is possible to execute the Fail Reset via a control without delay after appearance of the error.