Which products are affected?
8400 BaseLine D (as of firmware V2.2)
Function description
By means of the RLQ function a fail-safe reversal of the rotation direction can be implemented via two digital inputs.
Input RLQCw Input RLQCcw Function (SetSpeedCcw / SetQickstop)
False False Quick stop active (False / True)
True False CW rotation (False / False)
False True CCW rotation (True / False)
True True The previous selection of the rotation direction remains unchanged (no change / False)
(e. g. DIx = 0 V = False; DIx = 24 V = True)
Applications
Fail-safe reversal of the rotation direction
The following options have been prepared to operate this function assignment:
• Selection of the control mode C0007 = 16 (see picture below) or
• Individual function assignment via the following configuration codes
C0701/17 = 13 (Config. LA_NCTRL: bRLQCw connected to digital input DigIn_bIn3)
C0701/18 = 14 (Config. LA_NCTRL: bRLQCcw connected to digital input DigIn_bIn4)
Note:
In order to avoid that individual configurations are assigned twice, assign both parameters C0701/04 and C0701/05 with 0.