FB CDATA, drifts in case of master values with a negative sign (elimination)

Which products are affected?
9300 servo cam profiler V7.1

Application
Cam drives with master frequency coupling or a master frequency signal via system bus.
Operation with master speed and negative sign at FB CDATA

Description
Drifts can be avoided by parameterising code C1338/2 = 2.
According to the default parameter setting under CDATA the master value integrators are internally set to and kept on 0 when the CDATA-X-RESET input is set.
Incremental deviations of the position signal or master signal at the CDATA-DFIN input are thus no longer considered. A drift may be the result. The behaviour especially appears in case of backwards running master signals, e. g. via FB DFIN.
Thanks to parameter C1338/2 ('XIN-Mode') which has been included in the software as of version V3.1 a function avoiding the faulty behaviour is available. However, this is not documented separately. The documentation will be adjusted in the course of the next revision.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200604171/1/