Digital frequency filter PT1-2 (elimination)

Which products are affected?

9300 Servo cam, version 3.4

Eliminated function restriction

The calculation for filtering / delay of a master frequency signal vi a the filter was corrected.

Oscillations on a digital frequency signal can be filtered by using master frequency signal without using the position reference. The increments to be output delayed are saved internally.

Attention:
The internal memory can store a position difference up to 2147483647 (2^31 - 1) increments.After this difference was exceeded there will be a loss of the defined position (position overrun). In this case the function block is to be reset via the input PT1-2-RESET.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20036331/1/
Contact form