Position mode can be controlled via function list (0x2631:xxx) & NetwordIN1 (0x4008:001) & Positioning Control Word (0x5030:010)

Functional Extension:

The positioning functions can be controlled in various ways.

The following control options are available:

  • Function list (0x2631:xxx)
  • NetWordIN1 (0x4008:001)
  • Positioning Control Word (0x5030:010)

Note: 

  • Control via function list is only permitted if network control is not active (0x2631:037 = FALSE).
  • Control via NetWordIN1 and the positioning control word is only possible when network control is active (0x2631:037 = TRUE).
Regardless of which control source the commands come from, the resulting signals are displayed in the positioning control word 