i950 TA ElectronicGearbox: Setting the position of the virtual master causes a speed jump at DFOUT

     

Corrected from:

i950 Servo-Inverter (from V2.1, in Preparation)


Behavior of the new version: 

There is no sudden change in speed at the DF_OUT when the Master Value source is switched.


Description of the behavior: 

A sudden change in speed occurs in DFOUT.


Conditions under which the behavior occurs: 

Setting the position of the virtual master, e.g., when switching the conductance source


Affected products: 

i950 Servo-Inverter with TA ElectronicGearbox

 

Short-term measure, recommendations, evaluation: 
Only switch the reference source in the DF Master when the slave drives are disengaged.