Error message 'PDB file is incompatible (...)' when downloading a GDC file
Corrected from:
-
Behavior of the new version:
-
Description of behavior: Downloading a parameter set file in 'GDC' format is aborted with the following message:
PDB file is incompatible (...).
Conditions under which the behavior occurs: The behavior described above can occur if a parameter set file in 'GDC' format has been created with the PLC Designer or EASY Starter from the Lenze controllers or Servo Inverter i950 and this is downloaded with the EASY Starter or EASY Application Loader.
Affected products: PLC Designer from V3.28 PLC Designer from V4.0
Short-term measures, Recommendations, evaluation:
Instead of a parameter set file in 'GDC' format, create a device application (LDA format). This also contains the parameter set for the Lenze device. This LDA file can be easily downloaded using EASY Starter and/or EASY Application Loader.