OPC UA with c430

Function extension:

 c430 support OPC UA with following capabilities:

=> max. number of external sessions                              4
=> max. number of subscritions per sessions                10
=> max. number of monitored items per subsribtions 1000
=> max. sum number of monitored items                       4000 + 200 for engineering access
=> max. sum number of subscritptions                           10 + 2 for engineering access
=> min. publishing interval                                                200 ms
=> min. sampling interval                                                   200 ms

For more than one OPC UA client - server connection, 100 application credits are required when using c430.


Support of the "PubSub" feature. 
You need 100 application credits for Pub/Sub communication - although only one client-server connection is used.
(This is the same license as for more than one OPC UA client / server communication.)


Detailed information can be found in the enclosed documentation - in the chapter "OPC UA Server" and "OPC UA PubSub".


Contained in following products:

 c430

Application:

 OPC UA communication

 



URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300464/1/