No reservation of application credit for optional fieldbus interface at runtime
Corrected from:
-
Behavior of the new version:
-
Description of the behavior:
No communication is possible via the optional EtherCAT slave or Profinet fieldbus interface.
Conditions under which the behavior occurs:
The behavior occurs when the application credits required for the optional fieldbus interface are sent via the block L_ILMP_SetAppCreditConfiguration of the L_ILMP_LicenseManager library from the PLC project.
Affected products:
Cabinet Controller c430 from V1.11
Short-term measures, Recommendations, Rating:
If you want to use the optional fieldbus interface, select in the License Manager of the object 'FAST_System_Configuration' the configuration 'Static AC Configuration' to assign the application credit in the field 'AC Device Feature',