Recipe management: error message when loading recipes from device
Corrected from:
Cabinet Controller c520 V1.11
Cabinet Controller c550 V1.11
Servo inverter i950 V1.9
Behavior of the new version:
Recipes can be loaded without an error message if the following path was previously specified to save the recipe data in the 'RecipeManager' of the PLC Designer: ./PlcBootProject/Recipes
Description of the behavior:
The error message appears when uploading a recipe:
No recipe files with the extension xxx.csv were found in the runtime directory $IecFilePath$
Conditions under which the behavior occurs
The above error message can occur when uploading previously saved recipe data from the device.
Affected products: Cabinet Controller c520 Cabinet Controller c550 Servo inverter i950 PLC (0x4000:0 = TA User [10000]