Task configuration - Monitoring: Element jitter does not show instantaneous value (behoben ab V1.7)

Corrected from:
Cabinet Controller c520 V1.7
Cabinet Controller c550 V1.7

Behavior of the new version:
In the 'Monitoring' tab of the 'Task Configuration' object in the device tree and in the 'Task_Info2' structure of the 'CmpIecTask' library, the instantaneous jitter of the last cycle is displayed.

What happens? 
In the 'Monitoring' tab of the 'Task Configuration' object in the device tree and in the 'Task_Info2' structure of the 'CmpIecTask' library, the sum of maximum and minimum jitter is displayed in the 'Jitter' element. The instantaneous jitter of the last cycle is not displayed.
 
When does the behaviour occur? 
The behaviour occurs in the affected products.
 
Which products are affected? 
Cabinet Controller c300 from V3.20
Cabinet Controller 3200C from V3.20
Cabinet Controller c520 to V1.6
Cabinet Controller c550 to V1.6
Cabinet Controller c750 to V1.6
Panel Controller p300 from V3.20
Panel Controller p500 from V3.20
Servo Inverter i950 from V1.3

Short-term measures: 
None
 
Evaluation / recommendations:
The value of the jitter in the last task cycle cannot be evaluated due to this function restriction. For diagnostic purposes, the maximum jitter can be used.