i950: Boot application is deleted after an exception occurs in the PLC application (corrected from V01.08.00)

Corrected from:
Servo Inverter i950 FW: from V01.08.00 

Response of the new version:
After an exception in the PLC application and subsequent mains switching, the boot application is no longer deleted by mistake.

 
What happens?
The boot application contains the PLC program that is loaded when switching on.
In rare cases, an exception in the PLC processing can cause the boot application to be deleted. 

When does the behaviour occur?
  • An exception has occurred in the PLC processing and 
  • then the then the unit is switched off and restarted.
Which products are affected?
Servo Inverter i950 FW

Short-term measures / evaluation / recommendations:
In rare cases, an exception error in the PLC processing can lead to the boot application being deleted. 
In this situation, the machine can only be restarted after the boot application has been restored.
The boot application must therefore be transferred to the machine again, e.g. by a project download with the PLC Designer.