L_TS2P_SyncAndCorrection: The correction of the gear factor is frozen (corrected from V3.29.0)

Corrected from:
Library L_TS2P_TechModulesSynchronizingCamming (from V03.29.00). 
(Update via Easy Package Manager)

Response of the new version:
The gearbox factor correction permanently calculates the optimal value of the gearbox factor correction. Even if the maximum value is reached in the meantime during operation, the gear factor correction does not remain at this value, but can subsequently reach smaller values again if the statistical deviation of the marker error becomes smaller again.

What happens?
The value of the gear factor correction is no longer updated.

When does the behaviour occur?
When the gear factor correction reaches its limit (scPar.lrMaxGearFactorCorrMaster), it remains at the value. No further calculation of the correction value takes place.

Which products are affected?
L_TS2P_SyncAndCorrectionBase from library L_TS2P_TechModulesSynchronizingCamming  

Short-term measures:
Increase of the maximum permissible gear factor (scParlrMaxGearFactorCorrMaster).

Evaluation / recommendations:


Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200369/1/