L_MC1P: Touch probe (TP) via encoder sporadically determines a wrong TP position (corrected from V03.26.00)

Corrected from:
Library: L_MC1P_MotionControlBasic (FAST Motion) as of V03.26.00
              (Update via Package Manager)
 
Response of the new version:
Touch probe function: The TP position is now always determined correctly, matching the occurrence of the TP event.

 
What happens?
Touch probe function: Sporadically, an incorrect touch probe position is determined.

When does the behaviour occur?
  • Use of the touch probe function and
  • External encoder (FreeEncoder or i950 encoder axis) as position source for TP position
  • Touch probe source is an externally connected motion axis
Which products are affected?
Library: L_MC1P_MotionControlBasic (FAST Motion)
 
Short-term measures / evaluation / recommendations:

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200340/1/