L_MC1P: Touch probe (TP) and external position encoder: encoder zero pulse cannot be evaluated as touch probe (TP) (corrected from V03.26.00)

Corrected from:
Library: L_MC1P_MotionControlBasic (FAST Motion) from V03.26.00
             (Update via Package Manager)
 
Response of the new version:
i950: The zero pulse from the external position encoder at i950 slot B can now also be evaluated as a position source for the touch probe function 'MC_Touchprobe'.

 
What happens?
Touch probe function and external position sensor (application feedback):
Using the zero pulses from the second encoder at i950 slot B as a position source for the touch probe function does not work.
The message "InvalidTpSource" is displayed at the ErrorID output.

When does the behaviour occur?
  • Encoder axis serves as position source for the touch probe function (encoder axis at axis input of FB 'MC_Touchprobe')
  • Configuration MC_TRIGGER_REF:
    - TouchprobeSource   = 4 (ExternalTPFromAxis)
    - TouchPorbeSignal     = 3 (zero pulse external Position encoder)
    - ExternalTPFromAxis = i950_Motion_Axis
Which products are affected?
Library:  L_MC1P_MotionControlBasic  (FAST Motion)
 
Short-term measures / evaluation / recommendations: