L_TS2P_FlyingSaw: xSyncInInstant does not work correctly after switching on again (corrected from V3.26.0)

Corrected from:
Library: L_TS2P_TechModulesSynchronizingCamming (from V03.26.00)

Response of the new version:
After xSyncInInstant, synchronisation to the material position takes place immediately. This also applies after the process has been aborted, e.g. by xAbort.
What happens?
The target position to which xSyncInInstant synchronises is not correct after the process is stopped or cancelled.
 
When does the behaviour occur?
See description of behaviour.
 
Which products are affected?
L_TS2P_FlyingSawState from library L_TS2P_TechModulesSynchronizingCamming

Short-term measures:
-
 
Evaluation / recommendations:
-

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200308/1/
Contact form