L_IE1P_SetErrorSingle and i950: Error reset not possible and logbook entries are not made (corrected from V03.26.00)

Corrected from:
Library: L_MC1P_MotionControlBasic (FAST Motion) from V03.26.00
               (Update via Package Manager)
 
Response of the new version:
The FB 'L_IE1P_SetErrorSingle' now works as expected. 
Error messages can be set and reset in an i950 application and there is an associated logbook entry.

 
What happens?
FB L_IE1P_SetErrorSingle: 
With FB L_IE1P_SetErrorSingle it is not possible to send error messages in an i950 application. 
Although there is a reaction in the motion axis, there is no logbook entry and resetting the error message is also not possible.

When does the behaviour occur?
  • i950 application: Sending error messages via FB 'L_IE1P_SetErrorSingle' in an i950 application.
Which products are affected?
Library: L_MC1P_MotionControlBasic (FAST Motion)
 
Short-term measures / evaluation / recommendations:
As a remedy, either use FB 'L_IE1P_SetError' or
connect the ModuleHandler input of FB 'L_IE1P_SetErrorSingle' with the module handler of the axis (Axis.ModuleHandler).


Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202200306/1/