L_TF2P: i950 TA Table Positioning: Unexpected deceleration with dec = 36000 unit/s² at xAbort (fixed from V03.21.01)

Corrected from:
Library:   L_TF2P_TechModulesFollowingPositioning from V03.21.01
                      (Update via EASY Package-Manager)

Response of the new version:
Finished positioning is aborted at abort with the expected deceleration from the last profile.


What happens?
When aborting a positioning that was continued with the 'Finish positioning' feature, it is not stopped with the expected deceleration, but with dec = 36000 unit/s².
 
When does the behaviour occur? 
The behaviour occurs when the profile interruption and resumption occur in the following sequence:
 1. a positioning is started.
 2. positioning is aborted with Abort/xAbort
 3. positioning is continued with FinishPositioning/xFinishPositioning
 4. cancel positioning again with Abort/xAbort. Now the behavior occurs.
 
Which products are affected?
Library:   L_TF2P_TechModulesFollowingPositioning  V03.20.00 and V03.21.00
This library is part of the i950 TA Table Positioning of version V01.04.xx

Short-term measures:
Abort continued positioning not with xAbort but with xHalt.

Automatic Translation 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000344/1/
Contact form