L_MC1P and Jogging: Behavior when xJogPos and xJogNeg are set simultaneously (from V03.23.00)
Function extension:
Behavior of the jogging function (function blocks ABC, ManualJog, ManJogOpenloop): If both jogging inputs (xJogPos and xJogNeg) are set simultaneously while the jogging function is active, the drive decelerates to standstill. A warning is issued and the respective function block issues a corresponding error message. If one of the two jogging inputs is reset, the jogging movement is restarted from standstill in the selected direction.
Contained in which products? Library: L_MC1P_MotionControlBasic (FAST Motion) from V03.23.00.159
(Update via Package-Manager)
Application:
Use of the hand driving functionality (Manual Jogging) in a way that is not actually intended.
Intended manner: The manual movement of an axis is actually characterized by the fact that either direction of movement forward or backward, or direction of rotation right or left is specified - so only either xJogPos or xJogNeg is controlled and not both at the same time.