L_TB2P_AxisInterface: Some values are no longer output (Corrected from V3.21.0)

Corrected from:
Library:  L_TB2P_TechModuleBasic   from V03.21.00.07
                      (Update via Easy Package Manager)

Behaviour of new version:
The following values are now displayed again:
  • DC link voltage (lrDC_BusVoltage)
  • Motor current (lrActualMotorCurrent)
  • Motor temperature (lrActualMotorTemperatures)
What happens?
The following output values are no longer displayed:
  • DC link voltage (lrDC_BusVoltage)
  • Motor current (lrActualMotorCurrent)
  • Motor temperature (lrActualMotorTemperature)
When does the behaviour occur?
The FB L_TB2P_AxisInterface is used in a PLC application or project template.
 
Which products are affected?
Function block L_TB2P_AxisInterface from library L_TB2P_TechModuleBasic (from 3.20.0.27)
 
Short-term measures:
Use library L_TB2P_TechModuleBasic 3.19.0.53 or older
 
 
Or alternatively:
Set the following inputs of the Fb L_TB2P_AxisInterface to the value "TRUE".
xMonitoringActMotorCurent,
xMonitoringDCBusVoltage,
xMonitoringThermalLoadDevice,
xMonitoringThermalLoadMotor,
xMonitoringActMotorTemperatures
Use project template 3.20.0.11
 