i950 ES: When switching on, an incorrect product code is briefly displayed under 0x1018:2 (fixed as of V01.04.01)

Corrected from:
Servo Inverter i950 FW: from V01.04.01.1417
 
Response of the new version: 
When switching on, the product code is now correctly displayed under parameter 0x1018:2.
The cause was that the product code of the temporary application was saved by mistake when switching off. 
 
What happens?
i950 ES: When switching on, an incorrect product code is displayed under 0x1018:2 for a short period.
The user TA is first displayed as valid for 5 seconds and only then the actually existing TA.
 
When does the behaviour occur?
The procedure is as follows:
  1. Set and save any TA via Easy-starter in Index 4000.
  2. Download your own application with the PLC Designer and do NOT save it as a boot project.
  3. Switch the unit off and on again.
The cause is that the product code of the temporary application is saved when it is switched off and not that of the saved one.

Which products are affected?
Servo-Inverter i950 FW
 
Short-term measures / Evaluation / recommendations: