Corrected from: i950 servo inverter FW: as of V01.03.07.1252
Response of the new version:
0x2822:3 = 1 also resets the error displayed in 0x2010.
What happens?
0x2822:3 =1 does not reset the error displayed in 0x2010 although the error can be acknowledged.
When does this behaviour occur?
The behaviour occurs whenever an error has been triggered and the error is to be reset via 0x2822:3.
Which products are affected?
i950 servo inverter FW
Short-term measures:
Reset the error via 0x2841:0 = 1 or control word (0x6040).
Evaluation/recommendations:
The error reset via the 'Reset' function in the EASY Starter 'Diagnostics' dialog and via bit 7 in the control word TA does not work as expected.
These options are typically used by the user.