Digital output levels change for a short time when downloading parameters via the EasyStarter or Engineer

Corrected from:
  • Inverter Drives 8400 motec V10.00.00 
Response of the new version:

When the same values are written, the default settings are no longer loaded for a short time. Thus, downloading parameters can no longer lead to a change of the output levels.

 
What happens?
When downloading parameters via the Engineer or EasyStarter, the level of the digital outputs may change for a short time. All outputs under C00621/x are affected.
 
When does this behaviour occur?
When downloading parameters, the outputs are reset to their default settings first and then overwritten with the new values. This may lead to a short-time level change.
 
 
Which products are affected?
  • Inverter Drives 8400 motec
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800019/1/