Bit17 POS_dnState.bRev without function

Corrected from:
  • Servo Inverter 9400 HighLine with firmware V14.08.00 and higher
  • Servo Inverter 9400 Servo PLC HighLine with firmware V08.08.00 and higher
Response of the new version:
 
Bit17 POS_dnState.bRev=TRUE if the target is in the opposite direction of the current setpoint speed when changing a profile. 
 
What happens?
 
In the case of a profile change, bit 17 bRev 'Reversing active' does not indicate that the target is not in the same direction as the current setpoint speed.
 
When does this behaviour occur?
 
The status is always FALSE.
 
Which products are affected?
  • Servo Inverter 9400 HighLine with a firmware lower than V14.08.00
  • Servo Inverter 9400 Servo PLC HighLine with a firmware lower than V08.08.00
Short-term measures:
 
None
 
Evaluation/recommendations:
Limited diagnostics
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700401/1/