L_TT1P_TablePositioning: xTPOutOfWindow is not set (eliminated from V3.19.0)

Eliminated from:
Library: L_TT1P_TechnologyModules_LM from V03.19.00.25
                    (Update via Easy Package Manager)
 
Behaviour of new version:
The touchprobe can now also be used if the integrated visualization element for the technology module is used.
 
What happens?
xTPOutOfWindow remains FALSE.
 
When does this behaviour occur?
A profile with touch probe is replaced. In scProfiles, the touch probe window is set to a certain range (e.g. 0-300). 
Touch probe is detected outside of the set window.
The integrated visualization element for the technology module is used.
 
Which products are affected?
L_TT1P_TablePositioningBase in the L_TT1P_TechnologyModules_LM library (V3.13.0.7 and higher)
 
Short-term measures:
As long as the technology module is controlled directly from the application, this functional restriction does not occur.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700220/1/