PT1000 temperature sensor can be selected

Function extension:
In the future, KTY temperature sensors will no longer be available. This is why, we are changing over to PT1000 temperature sensors.
For new servo motors, the PT1000 can already be selected from the motor catalogue.
For existing motors with resolver feedback, a PT1000 can be selected in code C01190/1.
For existing motors with encoder feedback, a PT1000 can be selected in code C01190/2.
The selection of code C01190 has been extended as follows:

 - 5: PT1000 and

 - 6: PT1000 + 2xPTC150

Contained in which products?

  • Inverter Drives 8400 TopLine from V17.00.00

Application:

Whenever using a motor with PT1000 temperature sensor.