L_TT1P_ElectricalShaftPos: lrSyncInDist parameter is not updated (eliminated from V3.13)

Eliminated from:
L_TT1P_TechnologyModules_LM (ab V3.13.0.7)
 
Behaviour of new version:
After a change in parameter sPar. lrSyncInDist the axis with couples this distance at a next engagement via xSyncInstant.
 
What happens?
After changing the lrSyncInDist parameter, the axis does not clutch in again with the "old" distance.
 
When does this behaviour occur?
xSyncInstant is used for clutching in. The lrSyncInDist parameter is changed between two clutch-in processes.
 
Which products are affected?
L_TT1P_ElectricalShaftPos technology module from the L_TT1P_TechnologyModules_LM library (from V3.12.0.9)
 