Entry of Imax values > Irated

Corrected from:
  • Inverter Drives 8400 motec V08.00.00.00 

 Response of the new version:

When selecting Imax (C00022) values higher than the maximum value of the inverter, C00022 will be limited to the maximum value (200% rated inverter current). No error message will occur.
In addition, C00022 will be limited at a fixed switching frequency of 16kHz (C00018) and 480V mains voltage (C00173).
 
What happens?
If values higher than the maximum value (higher than 200% rated inverter current) are selected in C00022 (Imax), the "Unknown error code AIF-Mode6" error message appears and the value is not accepted. When using the Engineer and access via CAN, C00022 can no longer be changed as a result (C00022 becomes invalid/red).
 
When does this behaviour occur?
The behaviour occurs when selecting Imax values > Irated
 
Which products are affected?
  • Inverter Drives 8400 motec < V08.00.00.00 
Short-term measures:
-
 
Evaluation/recommendations:
-

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201600041/1/