Function extension:
Two new monitoring functions have been implemented in the i700 servo inverter:
- Function for monitoring the system deviation of the position controller (following error)
0x2D51:6 Activation and setting of the response 'Fault' or 'Warning'
0x2D51:4 Tolerance in degrees
0x2D51:3 Trigger threshold
- Function for monitoring the system deviation of the speed controller
0x2D51:3 Activation and setting of the response 'Fault' or 'Warning'
0x2D51:1 Tolerance in rpm
0x2D51:2 Trigger threshold
Contained in which products?
- i700 servo inverter from V01.09.03.10964
Application:
The new monitoring functions are particularly designed for applications in which the i700 is operated under third-party controllers.
The monitoring function for monitoring the system deviation of the position controller can be used as following error monitoring.