SSI encoder evaluation, extension of the number of status bits to 3
Which products are affected?
Inverter Drives 8400 TopLine from firmware version 14.00.00.00
Functional description
The number of evaluable status bits for the SSI encoder has been extended to 3 bits. In codes C426/8+9, the bit to be evaluated is defined in the SSI data stream.
If the evaluation of a status bit is to be completely deactivated, the value "32" is to be entered in the corresponding code. Like this, the status bit always has the value "0"