ApplicationTemplate: Apps in the "Append Machine Module Task" dialog are not sorted in ascending order (corrected from V3.12)

Corrected from:
PLC Designer V3.12
ApplicationTemplate project template V3.12
ApplicationTemplate packML project template V3.12
 
Response of the new version:
In the "Program Organization Unit" field of the "Append Machine Module Task" dialog, the module applications are sorted in ascending order.
 

What happens?
In the "Append Machine Module Task" dialog (menu command "Create Task Call" in the context menu of the "A11_ModuleAppCalls" folder), instead of module application App1, module application App2 is inserted into the task call (MAC_Task_xxx).

 

When does this behaviour occur?
In the "Program Organization Unit" field of the "Append Machine Module Task" dialog, module application App2 is displayed over App1. Since the "Name" column in the field is so narrow that the number of the module application is no longer visible, it may happen that the wrong App is selected and inserted into the task call.

 

Which products are affected?
PLC Designer V3.6
ApplicationTemplate project template V3.6
ApplicationTemplate packML project template V3.8

 

Short-term measures: 
Enlarge the "Name" column in the "Program Organization Unit" field in the "Append Machine Module Task" dialog.

 
Evaluation/recommendations:
When configuring the project, the wrong module application may be accidentally inserted into the task calls.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400324/1/