VisiWinNET 6.5.X: FNumPad - variable-dependent unit switch-over function does not work (corrected from Version 6.5.4)

Corrected from:
VisiWinNET Version 6.5.4
 
Response of the new version:
Variable-dependent unit is shown correctly in FNumPAD

  

What happens?
When selecting the variable-dependent unit switch-over function, the unit is not displayed in the FNumPad.

When does the problem occur?
The problem occurs if variable-dependent unit switch-over has been configured and the FNumPad is used.

Which products are affected?
The templates for the FNumPad in the Lenze and the system default version.

Short-term measures/recommendations:
Change the code.
Lenze FNumPad template ~line 275:
System default template line 280 :

Not correct:   unit = varIn.Unit.Text.DisplayText
Correct: unit = varIn.Unit.DisplayText 


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400215/1/