Cam online change only possible for the first 48 products

Corrected from:
9400 HighLine from firmware version 11.00.10.00
9400 Servo PLC from firmware version 05.00.10.00

Response of the new version?
The value range of Product selection for change C2911 has been extended to 0..255. Like this, now all 255 possible products can be selected for the cam online change.


 

Which products are affected?
Servo Inverter 9400 HighLine with a firmware version < 11.00.10.00
Servo Inverter 9400 ServoPLC with a firmware version < 05.00.10.00

What happens?
For the Product selection for change parameter C2911, no value greater than 47 can be set. Like this, only the first 48 products of 255 possible products can be achieved during the cam online change.
When does the problem occur?
At each attempt to parameterise C2911>47.

Diagnostics options?
The permissible value range is for instance shown in the Engineer in the information window under the parameter list in the 'All parameters' tab. Here the value range 0…47 is displayed.
Short-term measures/recommendations?
None.

Evaluation:
During the cam online change only the first 48 products of 255 possible products can be changed over. The online change with more than 48 products is only occasionally used.