Deactivation of the motor phase failure monitoring by C599=100%

Which products are affected?
9400 HighLine from firmware version 11.00.10.00
9400 Servo PLC from firmware version 05.00.10.00
 
Functional description
The permissible value range of the parameter C599 'Motor phase failure threshold' has been extended from 1…10% to 1…100%. This renders deactivation of the monitoring function during operation with the setting C599=100% possible. Monitoring before the operation (test signal after controller enable) remains active.
 
Applications                              
Monitoring of a motor phase failure before the operation.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400104/1/
Contact form