Starting value C122 for motor overload according to UL specification during operation

Which products are affected?
9400 HighLine from firmware version 11.00.10.00
9400 Servo PLC from firmware version 05.00.10.00
 
Functional description
After mains switching, the thermal model of the I²xt motor monitoring is initialised with the starting value parameterised in C01197
 
Applications                              
Improved motor protection via the motor overload monitoring (I²xt). Installation in accordance with UL requires the device functionality.​

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201400103/1/