Improved parameterisation for linear Hiperface encoders

Which products are affected?

8400 TopLine: FW version 13.00.00.00
 
Functional description
The settings for the Hiperface encoder have been extended by C1111/3 LS_MultiEncoder: Traverse path encoder increment. Here the distance in units is to be entered, which is covered when the number of encoder increments parameterised in C420/3 has been passed through.
The required parameterisation for linear Hiperface encoders has thus been clearly simplified in comparison to the previous version.
 
Applications
Position control with linear Hiperface encoders such as the SICK XKS09 Bowden wire encoder or Sick DME5000 laser encoder.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201304829/1/