Variable values are not updated after restarting the PLC (corrected from V3.7)

Corrected from:
3200C controller V3.7 
p500 controller V3.7
VisiWinNET V6.5.2 
 
Response of the new version:
If the visualisation of a Lenze controller accesses PLC variable values of a second Lenze controller, the variable values will be updated correctly after restarting the PLC on the second controller.
 
What happens?
The visualisation does not update the data displayed.

When does the problem occur?
The visualisation of a Lenze controller accesses PLC variable values of a second Lenze controller. After restarting the PLC on the second controller, the variable values of the second controller are no longer updated by the visualisation.

The function restriction does not occur after an interruption of the connection.

Which products are affected?
3200C controller V3.5 and higher
p500 controller V3.5 and higher

Possible diagnostics:
None

Short-term measures/recommendations:
Restart the visualisation once again.

Evaluation:
PLC variable values of a second controller are no longer updated after restarting the PLC.