Motor temperature display: Display range of -666...+666 °C not specified correctly in documentation (eliminated from V1.5.6)

Fixed as of:
- i700 servo inverter, documentatin of version  V01.05.06.9665
 
Behaviour of the new version:
The documentation has been updated.  

What happens?
The displayable temperature range actually covers the range from -666 to +666 °C. So far, a smaller range of +/-255 °C has been specified in the documentation.
In the event of an open circuit of the temperature sensor, not 255 °C but 666 °C are displayed as current motor temperature under 0x2D49:5.

When does the problem occur?
Always.

Which products are concerned?
- i700 servo inverter  ≤ V01.04.00.9125

Short-term measures/recommendations:
Not necessary.

Assessment:
The above-described problem does not have any direct effects on the drive features.
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201303182/1/
Contact form