Eliminated from:
Servo inverter i700 V01.02.03.8426
Behaviour of the new version?
The i700 servo inverters connected to the EtherCAT master can be started without problems after the firmware update for i700 servo inverters.
What is the response?
After the EtherCAT master is started, the i700 servo inverters connected to the master report the error code '0xFF00' (fatal internal error).
When does the problem occur?
The i700 servo inverter reports a fatal internal error if the firmware of the servo inverter is updated to firmware version V01.01.01.
Which products are affected?
Servo inverter i700 ≤ V01.01.02.7828
Short-term measures/recommendations?
Reset the error message by mains switching (24V supply) of the i700 servo inverter. In spite of this error message, the firmware has been updated successfully in the servo inverter.
Evaluation: