CAN BusOff error in case of frequent NMT reset node / reset com (eliminated from V5.0 onwards)
Eliminated from:
StateLine / HighLine with firmware version V05.01 or higher
Behaviour of the new version?
No error response if the above-mentioned telegrams are frequently transmitted.
Which products are affected?
8400 StateLine / HighLine with FW < 05.01
What happens?
The controller mistakenly detects a BusOff status for 1 ms and may generate an error message.
When does the problem occur?
If an NMT telegram, a reset node or reset communication are received in quick succession.
Possible diagnostics?
Display CE04 BusOff
Short-term measures / recommendations?
Configure the BusOff error message as Off or Warning (C00592/2).
Do not subject the bus to NMT telegrams, reset node or reset communication in quick succession.
Evaluation:
The error can be avoided if the recommendations are followed. The transmission of the above-mentioned telegrams in short cycles is not wise and very rare.
Taxonomy:
8400 HighLine frequency inverters
,
8400 StateLine frequency inverters
AKB-ID:
201014991
Last update:
2023/09/09
Category:
Version Informations