PS01 error message during operation (eliminated from V5.0 onwards)

Eliminated from:
StateLine with firmware version V05.01 or higher

Behaviour of the new version?
This function restriction is eliminated with the above-mentioned firmware version.



Which products are affected?
8400 StateLine with FW < 05.01

What happens?
During operation, the 'PS01 – No memory module' error message is sporadically issued although the memory module is properly available in the device.

When does the problem occur?
When an 8400 StateLine has been connected to a CAN bus with a pending CAN sync signal.

Possible diagnostics?
Logbook entry

Short-term measures / recommendations?
None (switch-off CAN sync if necessary)

Evaluation:
PS01 is a warning which leads to Logbook entries and warnings but does not limit the operational performance of the inverter.

Information taken from chapter 1.1.37 of Service Message No. 16/2010.