Bit assignments of the digital outputs have been extended
What products are concerned?
9400 HighLine Firmware V7.x TA CiA 402
L-force Engineer
Functional description
The status of the digital outputs is indicated in index I-60FE/1.
I-60FE/1 Bit 1 = dig. out 2
I-60FE/1 Bit 2 = dig. out 3
I-60FE/1 Bit 3 = dig. out 4
Applications
Via the digital outputs, status information of the application in addition to fieldbus networking can be subjected to further processing. Digital output 1 continues to be reserved for activation of the brake by means of a contactor.