Trip reset with C0043=0 via keypad is not possible (eliminated from V5.0)

Eliminated from:
ECS power supply module ECSxE, operating system V5.0

Behaviour of the new version?
A pending fault can now also be reset via keypad by writing C0043 = 0.




Which products are affected?
ECS power supply module ECSxE, operating system <= V4.0

What happens?
Trip reset with C0043=0 via keypad is not possible.

When does the problem occur?
When executing a trip reset via keypad.

Possible diagnostics?
Trip cannot be reset via keypad.

Short-term measures/recommendations?
Execute trip reset via terminals, CAN MotionBus, CAN system bus, or GDC.

Evaluation
There are other possibilities to reset a pending fault, see above.