Motor data assistant: ¨C86 is not available in the XML list¨ error message in case of 9300 vector devices (remedied from V4.10)

Remedied from?
GDC 4.10, GDC 4.10 update and GDC 4.10 Easy in combination with 9300 vector 0.37…90 kW, firmware (FW) 7.1

Behaviour of the new version?
When a motor from the 'user motor list' is selected no error message is indicated.



Which products are affected?
GDC 4.9, GDC 4.9 update and GDC 4.9 Easy in combination with 9300 vector 0.37…90 kW, firmware (FW) 7.1

Function restriction?
When a motor from the 'user motor list' is selected the following error message is indicated:
=> LNZMOT~1; Motor parameter/general/C86 is not available in the XML list.

Note:
Code L-C0086 must not be observed when 9300 vector user motor data is loaded.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200605006/1/