Parameter set transfer, C0082, C0085 and C0092 are not transferred if the keypad is used (elimination)

Which products are affected?
9300vector 110…400 kW SW7.1

Eliminated function restriction:
If a parameter set was created on a 9300 vector device (110 … 400 kW) equipped with a software version ≤ V6.3 and saved in the keypad, the motor parameters under the codes C0082, C0085 and C0092 were not transferred when this parameter set was transferred to a 9300 vector basic device (110 … 400 kW) equipped with software version 7.0 since these codes have an additional decimal position as of software version 7.0. In case of these three codes the values which had been valid before the transfer remained unchanged.

If during a transfer via keypad it is detected that the parameter set comes from a software version ≤ V6.3 factor 10 is now considered in the normalisation routine for the parameter calculation after a parameter set transfer.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200604949/1/