Which products are affected?
9300 servo cam profiler V7.1
Applications
Cam drives and other servo applications which contain the register generation function and require a mark synchronisation in the register.
Description
The CDATA and CCTRL2 function blocks have been extended by the CDATA-TP-EDGE-SELECT and CCTRL2-TP-EDGE-SELECT inputs.
The TP sensors at DIGIN4 and DIGIN5 can be evaluated correspondingly by activating the inputs as follows:
FALSE = (negative edge) or
TRUE = (positive edge)